Settings Interface

The following are the various options in the settings interface and their descriptions:

Option Description

General

Boot Auto-start

When enabled, the software will automatically start when the computer boots up.

Auto-start Solution

Select the solution to auto-start.

Language

Switch software language. Currently supports Chinese, English, Japanese, and Korean.

Auto Set Time (Smart Camera)

System time calibration function, automatically set time is enabled by default. When users open the software interface in a browser, the system will automatically synchronize the current browser time to the smart camera system time. When the local system time is inaccurate, users can also manually set the date and time.

FTP Data Transmission

Remote Server IP

Set the remote server IP address.

Port Number

Set the remote server port number.

Username

Set the remote server username.

Password

Set the remote server password.

Enable Connection

Set the remote server transmission path.

Sync Data

Can choose to sync production data, camera data, runtime screenshots.

FTP Service Path

Set the FTP service transmission path.

Delete Local Data

Whether to delete local data after files are uploaded to the FTP server.

FTP Data Transmission

FTP data transmission will be automatically enabled after connection is established.

Software Authorization (Smart Camera)

Download Certificate

Download the current device’s RAC file.

Upload Certificate

Upload the encrypted RAU file.

File Storage

Production Record Information (GB)

Information table (*.epicrep) that records scheme execution data, including execution status and time, pose data, recognition results, and other data, used for subsequent quick problem analysis and local debugging and reproduction.

Storage capacity limit: Maximum 5GB. When exceeded, the system will automatically delete the oldest files to free up space.

Camera Raw Data (GB)

Camera data files (.epicraw), containing 2D images, 3D point clouds, depth maps, and camera parameters.

Storage capacity limit: Maximum 10GB. When exceeded, the system will automatically delete the oldest files to free up space.

There are three data saving modes: Save all data, Save OK data only, Save NG data only. Data will be stored in OK and NG folders created separately under the scheme directory according to type. NG data represents data where ATOM did not return data or motion planning had no results. When the set maximum storage capacity limit is exceeded, the system will automatically find and delete the oldest files.

Runtime Screenshots (GB)

Screenshots of the runtime interface are saved after scheme execution according to configuration.

Storage capacity limit: Maximum 5GB. When exceeded, the system will automatically delete the oldest files to free up space.

There are three data saving modes: Save all data, Save OK data only, Save NG data only. Data will be stored in OK and NG folders created separately under the scheme directory according to type. NG data represents data where ATOM did not return data or motion planning had no results. When the set maximum storage capacity limit is exceeded, the system will automatically find and delete the oldest files.

File Storage Path

Windows

Data collection and other file storage paths are all folders under the C:\Users\<username>\.transfertech\epic-pro\app_data\collection directory

Ubuntu

Data collection and other file storage paths are all folders under the /home/<username>/.transfertech/epic-pro\app_data\collection directory

Please replace <username> with your username